Sign in →

Test Code Test- multiple sources Test- multiple sources

Additional Codes

Epic EAP:

Collection Limitations

Urine is NOT an acceptable source for a patinet older than 1 month. For CSF specimens, use test code HSVC

Specimen Type

Varies

Specimen Required

 

 

Primary Source: Body Fluid

  Collection Container Preferred Volume Minimum Volume
Preferred

Sterile Vial

0.5 mL 0.5 mL
Alternate

Sterile Vial

0.5 mL 0.5 mL

 

 

Alternate Souce:  Genital

  Collection Container Preferred Volume Minimum Volume
Preferred

Culturette (for aerobic collections)

1 swab 1 swab
Alternate

Culturette (for aerobic collections)

1 swab 1 swab

 

 

Alternate Souce:  Vesicular Fluid

  Collection Container Preferred Volume Minimum Volume
Preferred

Culturette (for aerobic collections)

1 swab or 0.5 mL fluid 1 swab or 0.5 mL fluid
Alternate

Culturette (for aerobic collections)

1 swab or 0.5 mL fluid 1 swab or 0.5 mL fluid

 

 

Alternate Souce:  Respiratory Sources/Sites

  Collection Container Preferred Volumne Minimum Volume
Preferred

Sterile vial

1.5 mL 1.5 mL
Alternate

Sterile vial

1.5 mL 1.5 mL

 

 

 

Instructions for Collection and Transport

DO NOT USE VIRAL TRANSPORT MEDIA. ANY SPECIMEN COLLECTED IN VIRAL TRANSPORT MEDIA WILL BE REJECTED.

Collect Body Fluid and Respiratory specimens in a sterile vial and transport refrigerated.

Collect Genital specimens of the cervix, rectum, urethra, vagina or other genital sites using a sterile culturette and transport refrigerated.

Collect throat swabs using sterile culturette.

Another alternate source is 3mm of Tissue (indicate source) collect in a sterile vial containing 1.0-2.0ml of sterile saline and transport refrigerated.

Performing Lab

Send out lab to Mayo Medical

 

Assay Frequency

Monday - Saturday

Routine Turnaround Time

4 days, excluding weekends and holidays

CSR Storage Requirements

Deliver specimen to Sendouts immediately. Refrigerate specimen if held overnight.

Aliquot Requirement

 

Optimum: N/A