Sign in →

Test Code TS Type and Screen - St. Charles

Additional Codes

Epic EAP: LAB1919

Epic Description: TYPE & SCREEN

This code for St. Charles.  All other sites order TSE (LAB1919)

Synonym

Type & Screen

ABO/Rh & Indirect Antiglobulin (Coombs) Test

Collection Limitations

Pink EDTA preferred 6.0 mL tube is in stock in Central Supply. Tubes can be ordered from Central Supply. Lawson #74361

Specimen Type

Blood

Specimen Required

 

 

  Collection Container Preferred Volume Minimum Volume
Preferred

PINK, 6.0 mL EDTA

6.0 mL 6.0 mL
Alternate Lavender, EDTA 6.0 mL 6.0 mL

 

Instructions for Collection and Transport

Tubes must be labeled with the following information:

1. Patient’s complete name

2. Clinic Number

3. Location

4. Date of Collection

5. Collector’s I.D.

 

Tubes may be labeled with stamped or computer-generated labels or info may be handwritten. Do not centrifuge. Transport at room temperature. Refrigerate if holding overnight.

Performing Lab

Blood Bank Lab

Assay Frequency

24 hours

Routine Turnaround Time

40 minutes

CSR Storage Requirements

Transport specimens to Blood Bank. Do not centrifuge.

CPT Code Information

86900

86901

86850