Sign in →

Test Code Mayo: SM |Beaker: LAB2001 Smith (Sm) Antibodies, IgG, Serum

Important Note

Only available in the Lafayette region

Additional Codes

Epic EAP: LAB2001

Epic Description: ANTI-SMITH ANTIBODY

Reporting Name

Sm Ab, IgG, S

Useful For

Evaluating patients with clinical features suggestive of antinuclear antibody associated connective tissue disease and the confirmation of a diagnosis of systemic lupus erythematosus.

 

Testing for Smith antibodies is not useful in patients without demonstrable antinuclear antibodies.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.35 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reference Values

<1.0 U (negative)

≥1.0 U (positive)

Reference values apply to all ages.

Day(s) Performed

Monday through Saturday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86235

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SM Sm Ab, IgG, S 18323-6

 

Result ID Test Result Name Result LOINC Value
SM Sm Ab, IgG, S 18323-6

Report Available

1 to 3 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Heat treated Reject

Method Name

Multiplex Flow Immunoassay

Secondary ID

81358