Sign in →

Test Code IL2R Interleukin 2 Receptor (Soluble) by MAFD

Additional Codes

Epic EAP: LAB2643

Epic Description: INTERLEUKIN-2 RECEPTOR

Synonym

IL-2R

SIL-2R

Soluble Interleukin – 2 Receptor

Specimen Type

Serum/plasma

Specimen Required

Primary Source: Blood

  Collection Container Preferred Volume Minimum Volume
Preferred

Red, No Anticoagulant, No gel

6.0 mL 2.0 mL
Alternate Gold, Clot Activator with Inert Gel 6.0 mL 2.0 mL

 

 

 

Instructions for Collection and Transport

Centrifuge and separate serum from cells within 2 hours of collection. Aliquot into a plastic vial and freeze. Avoid freeze/thaw cycles. Transport frozen on dry ice. Store frozen if holding overnight.

Aliquot Requirements

Serum or Plasma

Optimum 1.0 mL

Minimum 0.4 mL

Performing Lab

Sendout Lab

Reference Lab: ARUP Laboratories, Referral code: 51588

https://ltd.aruplab.com/Tests/Pub/0051588

Assay Frequency

Sat-Sun

Routine Turnaround Time

1-4 days

CSR Storage Requirements

Centrifuge and separate serum from cells within 30 minutes. Aliquot into a plastic vial and freeze. Store frozen if holding overnight.

CPT Code Information

83520