Sign in →

Test Code FXMAU HLA Auto Flow Crossmatch

Additional Codes

Epic EAP: LAB2605

Epic Description: HLA AUTO FLOW CROSSMATCH

Synonym

Flow cytometric Auto Crossmatch

Collection Limitations

Jeff Hwy Campus: Collect Sunday through 8 A.M. Friday.

Remote Locations: Collect Sunday through Thursday.

Specimen Type

Blood

Specimen Required

 

 

  Collection Container Preferred Volume Minimum Volume
Preferred

3 – Yellow, ACD-A (Acid Dextrose Solution A) AND Red, No Anticoagulant, No gel

3 X 8.5 mL (Yellow Tubes); 1 X 6.0 mL (Red Tubes) Contact HLA Lab

 

Instructions for Collection and Transport

Gel tubes are not acceptable. Specimens must be received in HLA Lab within 24 hours and prior to 9 A.M. on Friday. Store at room temperature. Do not centrifuge, refrigerate, or freeze. Transport at room temperature.

Performing Lab

HLA Lab

Assay Frequency

Monday – Friday morning (Excluding holidays)

Routine Turnaround Time

10 days, excluding weekends and holidays.

CSR Storage Requirements

Contact HLA Lab. Store at room temperature in CSR Lab in HLA igloo. Do not freeze, refrigerate or centrifuge.